Loading image...


Ethanol Fireplaces
Create an instant talking point
Because bioethanol is clean-burning, EcoSmart Fire models do not need a chimney or a flue, or a utility connection – offering the ultimate in design simplicity and flexibility.
Whether you're creating a custom fireplace feature, renovating an existing fireplace, or looking for an out-of-the-box solution, we have an ethanol fireplace to suit your needs.
Ethanol Ranges
Loading image...


Environmentally-friendly
Fuelled by eco-friendly, readily available renewable energy – e-NRG bioethanol.
No flue, no chimney
Bioethanol is clean burning so you don't need to flue out any harmful emissions or install costly ventilation systems.
Loading image...


Architectural feature
Bioethanol’s lively dancing flame creates a striking focal point for interior designers.
Loading image...


Design versatility
Easily integrated into bespoke settings – from specially-made cabinetry, media units, walls, floating timber to stone benches and pillars.
The perfect fit
The streamlined design of the products synchronises effortlessly within award-winning architectural projects.
Loading image...

© InterContinental Yokohama Pier 8 Loading image...


Ventless design
No venting required so ethanol fireplaces fit apartments, renovations, and compact spaces.
Supplemental heating
Add cozy zone warmth with modern fire features to complement your primary heating system.
Powered by e-NRG
Premium liquid fuel engineered for clean, consistent flames with low odour and zero smoke.
Related Collections
Learn More
Ethanol Fireplaces
Bioethanol Fireplaces
Ventless Fireplaces
FAQ's
Are bioethanol fireplaces environmentally friendly?
Bioethanol fireplaces are environmentally friendly in ways that go beyond zero emissions. They produce no ash, soot, or residue, leaving nothing to dispose of, and their ventless design eliminates the environmental cost of infrastructure like chimneys, flue systems, or gas plumbing. The fuel comes from renewable agricultural byproducts: sugarcane, corn, grain, and beetroot.
Because combustion releases only the CO2 that the crops absorbed during growth, the fuel cycle is carbon-neutral. When combined with the fireplace's design durability and longevity, a bioethanol fireplace becomes a low-impact choice for years of use. EcoSmart Fire products meet international safety standards (UL 1370-16, EN 16647) and carry sustainability certifications across manufacturing, reinforcing the brand's commitment to responsible production.
What is the heat output of a ventless ethanol fireplace?
EcoSmart Fire ventless ethanol fireplaces deliver heat output ranging from approximately 2.5 kW to 6 kW (8,500–20,433 BTU/h), depending on burner size. Heat output correlates directly to burner dimensions: smaller configurations produce around 2.5 kW and heat zones of approximately 20 m² [215 ft²], while the largest burners reach 6 kW and warm spaces up to 60 m² [645 ft²] or larger.
Heat output is adjustable in real time via baffle inserts, so you are not locked at maximum output. You can dial flame intensity up or down to match your comfort needs. This matters for efficiency: over 90% of the heat generated stays in the room, as there is no flue to lose it through.
Fuel consumption ranges from approximately 0.5 L/h on lower settings to 2+ L/h at full output, with operating costs around USD 1.50 per hour depending on burner size and flame setting. For sizing, minimum room volumes start at 40 m³ [1,413 ft³] for the smallest burners, scaling up to 116 m³ [4,097 ft³] for the largest. Match your space volume to burner size to ensure comfortable zone heating.
Do bioethanol fireplaces produce carbon monoxide?
Bioethanol fireplaces produce no carbon monoxide during normal operation. Complete combustion converts bioethanol entirely into water vapour and carbon dioxide, and adjustable flame control across EcoSmart Fire's operating range does not alter this chemistry.
Carbon monoxide results from incomplete combustion, when insufficient oxygen prevents full oxidation of the fuel. EcoSmart Fire burners maintain complete combustion across the full output range. The flame arrestor integrated into the burner prevents fuel vapour flashback and sustains consistent burn conditions throughout each session.
Combustion by-products are carbon dioxide and water vapour, the same gases produced by normal breathing and candle combustion. UL 1370 (USA) and EN 16647 (Europe and UK) independently validate that EcoSmart Fire fireplaces meet safety thresholds for unvented indoor use.
Do ethanol fireplaces produce enough heat?
Yes, ethanol fireplaces produce genuine, clean-burning heat that meaningfully warms spaces. EcoSmart Fire bioethanol fireplaces deliver quantified heat output across burner sizes: compact burners like the AB3 produce 2 kilowatts (5,800 BTU/h) and warm spaces around 20 m² [215 ft²], whilst larger models like the XL900 output 4 kilowatts (15,000 BTU/h) and effectively heat areas up to 60 m² [646 ft²].
The real advantage lies in the ventless design: heat efficiency exceeds 90 per cent because all thermal energy stays in your room, unlike traditional vented fireplaces that lose approximately 30 per cent through the chimney.
To choose the right burner, match it to your room size. Smaller burners suit compact rooms around 20 m², mid-range burners heat spaces of 40–60 m² comfortably, and larger configurations work for open-plan interiors. Burner selection also affects burn duration, with most models running 7–14 hours depending on flame height; consider both your heating needs and intended use.
How much does it cost to run a ventless ethanol fireplace per hour?
Room-vented ethanol fireplace running costs depend on burner size and flame height, since combustion directly controls fuel consumption. Smaller burners consume around 0.31 litres per hour at minimum flame, mid-range around 0.5 L/h, and larger burners up to 1.1 L/h at full flame. At current bioethanol fuel pricing (typically USD $4-6 per litre retail), this translates to roughly $1.24-$6.60 per hour depending on the model and flame setting you choose.
The room-vented design gives you a real cost advantage: because there is no flue, 100 per cent of the combustion heat stays in the room. Every litre of fuel delivers its full thermal output directly into your space, with no heat loss up a chimney. This means lower fuel bills compared to traditional fireplaces at the same comfort level.
To minimise running costs, simply lower the flame height. Flame control is your cost control: it directly reduces consumption. For bulk fuel purchasing (200 litres or more), per-litre pricing drops significantly. Check e-nrg.com for current pricing and bulk rates.
What gases and emissions does a bioethanol fireplace produce?
Bioethanol fireplace emissions are limited to heat, water vapour, and a small amount of carbon dioxide, with no carbon monoxide, smoke, soot, or ash produced during combustion. The CO2 released is roughly equivalent to two burning candles, which means correctly sized rooms maintain clean indoor air without a flue or chimney.
Clean combustion does depend on fuel purity. High-grade e-NRG bioethanol burns as a complete reaction, producing a steady orange flame from start to finish without the residues that lower-purity fuels leave behind. That's why EcoSmart Fire bioethanol fireplaces won't stain ceilings, dull nearby finishes, or leave ash to clean up between uses.
What the by-products look like in practice:
- Water vapour: a slight, imperceptible rise in humidity, not visible condensation in a correctly sized room
- Carbon dioxide: trace amounts, comparable to candlelight at the same output
- No particulates: no smoke, no soot, no ash, no odour
Ventilation is about keeping fresh oxygen available for combustion, not venting harmful gases. Each burner has a minimum room size, from the VB2 at 45 m3 [1,589 ft3] up to the AB8 at 116 m3 [4,097 ft3], so adequate air supply is a matter of considered installation
Do bioethanol fireplaces need a chimney or flue?
Bioethanol fireplaces with adjustable flame control do not require a chimney, flue, or permanent ventilation system. The clean combustion of bioethanol releases only water vapour and a small amount of carbon dioxide, with no smoke or soot that would need extraction through a dedicated exhaust pathway.
What replaces the chimney is adequate room volume and natural air infiltration. Minimum room sizes are specified per burner. In very compact rooms, a window openable to 25 mm [1 in] or an adjacent open door provides sufficient air exchange.
This chimney-free design underpins the installation freedom EcoSmart Fire bioethanol fireplaces are known for: zero-clearance inserts, freestanding pieces, and existing fireplace conversions all become viable without structural works.
Can I refill my bioethanol fireplace while it's running?
No, never refuel your EcoSmart Fire bioethanol fireplace while it's running or hot. Bioethanol requires careful handling: even if the flame isn't visible, a common occurrence in daylight, the burner remains dangerously hot and volatile vapours persist long after the flame appears extinguished. Contact with any ignition source at this stage can cause serious injury.
Always allow the fireplace to cool completely for at least 60 minutes after shutting off before refuelling. The cool-down is part of the rhythm of responsible ownership. When refuelling, use only the approved Safety Nozzle adapter or Jerry Can with Safety Spout, never pour directly from a bottle over or near the burner. If you spill fuel, remove all ignition sources, open windows and doors for ventilation, wipe the area dry, and wait until it's completely dry before relighting.
UL 1370-certified EcoSmart Fire bioethanol fireplaces are designed for safe indoor use when operated correctly. Pairing the correct cool-down protocol with e-NRG bioethanol fuel ensures consistent performance and safety.
Can ventless fireplaces cause moisture problems?
Yes, room-vented bioethanol fireplaces do produce water vapour through combustion, and condensation can occur in spaces that are undersized or poorly ventilated. EcoSmart Fire's design addresses this directly: minimum room volume requirements are scaled to each burner's heat output, ensuring moisture disperses safely across the air volume rather than accumulating on surfaces.
Smaller burners (around 4 kW) need at least 110 m³ [3,885 ft³], whilst larger burners (13 kW) require 330 m³ [11,654 ft³] or more. This scaling ensures combustion byproducts, including water vapour and carbon dioxide, are diluted proportionally to the burner's output.
In properly sized rooms with normal air circulation (doors, windows, existing HVAC), condensation is not an issue. Problems arise only when a fireplace is oversized for its space or installed in a room with poor air exchange; matching the burner size to the room prevents either outcome.
Separately, ambient moisture from external sources, such as humid storage environments or spilled water, can contaminate the burner reservoir and prevent ignition. This is a maintenance concern distinct from normal combustion, resolved by draining, drying, and refuelling with fresh bioethanol.
What are the pros and cons of ventless fireplaces?
Ventless bioethanol fireplaces deliver room-vented performance without any of the infrastructure traditional installations require. There is no chimney, flue, or gas line, and combustion is clean, producing no smoke, soot, or ash. The gains are real: heat stays in the room rather than escaping through a flue, and the fireplace can be positioned almost anywhere, from apartments to open-plan living spaces. Managing the trade-offs is equally clear. Bioethanol combustion consumes oxygen, so the room must meet manufacturer-specified minimum volumes, and ventilation needs to remain adequate during use. These fireplaces are designed for supplemental heating, not as a primary heat source, and they require ongoing refuelling since no fuel line connects them. For spaces where a traditional fireplace is impractical, the room-vented ventless format offers genuine design freedom. The cost of that freedom is active fuel management and attention to room conditions during operation, both of which are clearly outlined in EcoSmart Fire's product documentation and third-party certified safety standards.








